6ES7318-3EL00-0AB0 CPU319-3 PN/DP, 1.4MB

Product Code: 6ES7318-3EL00-0AB0

Availability: In Stock

Price: $2,719.45
  
 
Artikelnummer 6ES7318-3EL00-0AB0
SIMATIC S7-300 CPU 319-3 PN/DP, CENTRAL PROCESSING UNIT WITH 1,4 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, MICRO MEMORY CARD NECESSARY
General information
Hardware product version 01
Firmware version V2.6.0
Engineering with
● Programming package STEP 7 V5.4 SP2
Supply voltage
24 V DC Yes
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
External protection for supply cables (recommendation) 2 A min.
Input current
Current consumption (rated value) 1 050 mA
Current consumption (in no-load operation), typ. 400 mA
Inrush current, typ. 4 A
I²t 1.2 A²·s
Power losses
Power loss, typ. 14 W
Memory
Work memory
● Integrated 1 400 kbyte
● expandable No
Load memory
● pluggable (MMC) Yes
● pluggable (MMC), max. 8 Mbyte
● Data management on MMC (after last programming), min. 10 y
Backup
● present Yes; up to 700 KB, maintenance-free
● without battery Yes; Program and data
CPU processing times
for bit operations, typ. 0.01 µs
for word operations, typ. 0.02 µs
for fixed point arithmetic, typ. 0.02 µs
for floating point arithmetic, typ. 0.04 µs
CPU-blocks
Number of blocks (total) 4 096; (DBs, FCs, FBs OBs, SDBs); the maximum number of loadable blocks can be reduced by the MMC being used.
DB
● Number, max. 4 095; Number range: 1 to 4095
● Size, max. 64 kbyte
FB
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
FC
● Number, max. 2 048; Number range: 0 to 2047
● Size, max. 64 kbyte
OB
● Size, max. 64 kbyte
● Number of free cycle OBs 1; OB 1
● Number of time alarm OBs 1; OB 10
● Number of delay alarm OBs 2; OB 20, 21
● Number of time interrupt OBs 4; OB 32, 33, 34, 35 (OB 35: smallest settable clock pulse = 500 µs)
● Number of process alarm OBs 1; OB 40
● Number of DPV1 alarm OBs 3; OB 55, 56, 57
● Number isochronous mode OBs 1; OB 61
● Number of startup OBs 1; OB 100
● Number of asynchronous error OBs 6; OB 80, 82, 83, 85, 86, 87
● Number of synchronous error OBs 2; OB 121, 122
Nesting depth
● per priority class 16
● additional within an error OB 4
Counters, timers and their retentivity
S7 counter
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset Z 0 to Z 7
Counting range
— can be set Yes
— lower limit 0
— upper limit 999
IEC counter
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
S7 times
● Number 2 048
Retentivity
— can be set Yes
— lower limit 0
— upper limit 2 047
— preset No retentivity
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present Yes
● Type SFB
● Number Unlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, total All, max. 700 KB
Flag
● Number, max. 8 kbyte
● Retentivity available Yes; from MB 0 to MB 8191
● Retentivity preset MB 0 to MB 15
● Number of clock memories 8; 1 memory byte
Data blocks
● Number, max. 4 095; Number range: 1 to 4095
● Size, max. 64 kbyte
● Retentivity adjustable Yes; via non-retain property on DB
● Retentivity preset Yes
Local data
● per priority class, max. 1 024 byte
Address area
I/O address area
● Inputs 8 kbyte
● Outputs 8 kbyte
of which, distributed
— Inputs 8 kbyte
— Outputs 8 kbyte
Process image
● Inputs 2 048 byte
● Outputs 2 048 byte
● Inputs, adjustable 2 kbyte
● Outputs, adjustable 2 kbyte
● Inputs, default 256 byte
● Outputs, default 256 byte
Subprocess images
● Number of subprocess images, max. 1
Digital channels
● Inputs 65 536
● Outputs 65 536
● Inputs, of which central 1 024
● Outputs, of which central 1 024
Analog channels
● Inputs 4 096
● Outputs 4 096
● Inputs, of which central 256
● Outputs, of which central 256
Hardware configuration
Number of DP masters
● Integrated 2
● Via CP 4
Number of operable FMs and CPs (recommended)
● FM 8
● CP, point-to-point 8
● CP, LAN 10
Rack
● Racks, max. 4
● Modules per rack, max. 8
Time of day
Clock
● Hardware clock (real-time clock) Yes
● battery-backed and synchronizable Yes
● Deviation per day, max. 10 s
● Backup time 6 wk; At 40 °C ambient temperature
Operating hours counter
● Number 4
● Number/Number range 0 to 3
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 hour
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes; With DP slave only slave clock
● to DP, slave Yes
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes; As client
1st interface
Interface type Integrated RS 485 interface
Physics RS 485
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 150 mA
Functionality
● MPI Yes
● DP master Yes
● DP slave Yes
● Point-to-point connection No
MPI
● Number of connections 16
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication Yes
— S7 basic communication Yes
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes; I blocks only
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode No
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
DP slave
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; with interface active
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
2nd interface
Interface type Integrated RS 485 interface
Physics RS 485
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 200 mA
Functionality
● MPI No
● DP master Yes
● DP slave Yes
● PROFINET IO Controller No
● PROFINET IO Device No
● PROFINET CBA No
● Open IE communication No
● Web server No
● Point-to-point connection No
DP master
● Transmission rate, max. 12 Mbit/s
● Number of DP slaves, max. 124
Services
— PG/OP communication Yes
— Routing Yes
— Global data communication No
— S7 basic communication Yes; I blocks only
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Equidistance mode support Yes
— Isochronous mode Yes; OB 61
— SYNC/FREEZE Yes
— Activation/deactivation of DP slaves Yes
— DPV1 Yes
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
User data per DP slave
— Inputs, max. 244 byte
— Outputs, max. 244 byte
DP slave
● GSD file The latest GSD file is available at: http://www.siemens.com/profibus-gsd
● Transmission rate, max. 12 Mbit/s
● Automatic baud rate search Yes; only with passive interface
● Address area, max. 32
● User data per address area, max. 32 byte
Services
— PG/OP communication Yes
— Routing Yes; with interface active
— Global data communication No
— S7 basic communication No
— S7 communication Yes
— S7 communication, as client No
— S7 communication, as server Yes
— Direct data exchange (slave-to-slave communication) Yes
— DPV1 No
Transfer memory
— Inputs 244 byte
— Outputs 244 byte
3rd interface
Interface type PROFINET
Physics Ethernet RJ45
Isolated Yes
Power supply to interface (15 to 30 V DC), max. 0 mA
Automatic detection of transmission speed Yes; 10/100 Mbit/s
Functionality
● MPI No
● DP master No
● DP slave No
● PROFINET IO Controller Yes
● PROFINET IO Device No
● PROFINET CBA Yes
● Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
● Web server Yes
● Point-to-point connection No
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
● Number of connectable IO devices, max. 256
● Send cycles 250 µs, 500 µs, 1 ms
● Updating time 250 µs - 128 ms (with send cycle of 250 µs); 500 µs - 256 ms (with send cycle of 500 µs); 1 ms - 512 ms (with send cycle 1 ms); minimum value of the send cycle is also dependent on the set communication share for PROFINET IO, on the number of I/O devices, and on the volume of configured user data.
Services
— PG/OP communication Yes
— Routing Yes
— S7 communication Yes; with loadable FBs, max. configurable connections: 16
— Open IE communication Yes; Via TCP/IP, ISO on TCP, and UDP
Address area
— Inputs, max. 8 kbyte
— Outputs, max. 8 kbyte
— User data consistency, max. 254 byte
Open IE communication
● Number of connections, max. 8
PROFINET CBA (at 50% communication load)
● acyclic transmission Yes
● Cyclic transmission Yes
Isochronous mode
Isochronous operation (application synchronized up to terminal) Yes; Via 2nd DP interface
Communication functions
PG/OP communication Yes
Global data communication
● supported Yes
● Number of GD loops, max. 8
● Number of GD packets, max. 8
● Number of GD packets, transmitter, max. 8
● Number of GD packets, receiver, max. 8
● Size of GD packets, max. 22 byte
● Size of GD packet (of which consistent), max. 22 byte
S7 basic communication
● supported Yes
● User data per job, max. 76 byte
● User data per job (of which consistent), max. 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported Yes
● as server Yes
● As client Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
● User data per job, max. See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5-compatible communication
● supported Yes; via CP and loadable FC
Open IE communication
● TCP/IP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 1 460 byte; with connection type 01H; 8192 bytes with connection type 11H
● ISO-on-TCP (RFC1006) Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 8 192 byte
● UDP Yes; via integrated PROFINET interface and loadable FBs
— Number of connections, max. 8
— Data length, max. 1 472 byte
PROFINET CBA (at set setpoint communication load)
● Setpoint for the CPU communication load 20 %
● Number of remote interconnection partners 32
● Number of functions, master/slave 50
● Total of all Master/Slave connections 3 000
● Data length of all incoming connections master/slave, max. 24 000 byte
● Data length of all outgoing connections master/slave, max. 24 000 byte
● Number of device-internal and PROFIBUS interconnections 1 000
● Data length of device-internal und PROFIBUS interconnections, max. 8 000 byte
● Data length per connection, max. 1 400 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min. 200 ms
— Number of incoming interconnections 100
— Number of outgoing interconnections 100
— Data length of all incoming interconnections, max. 3 200 byte
— Data length of all outgoing interconnections, max. 3 200 byte
— Data length per connection, max. 1 400 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min. 1 ms
— Number of incoming interconnections 300
— Number of outgoing interconnections 300
— Data length of all incoming interconnections, max. 4 800 byte
— Data length of all outgoing interconnections, max. 4 800 byte
— Data length per connection, max. 250 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap) 3; 2x PN OPC/1x iMap
— HMI variable updating 500 ms
— Number of HMI variables 600
— Data length of all HMI variables, max. 9 600 byte
PROFIBUS proxy functionality
— supported Yes
— Number of linked PROFIBUS devices 32
— Data length per connection, max. 240 byte; Slave-dependent
Number of connections
● overall 32
● usable for PG communication 31
— reserved for PG communication 1
— Adjustable for PG communication, min. 1
— Adjustable for PG communication, max. 31
● usable for OP communication 31
— reserved for OP communication 1
— adjustable for OP communication, min. 1
— adjustable for OP communication, max. 31
● usable for S7 basic communication 30
— Reserved for S7 basic communication 0
— adjustable for S7 basic communication, min. 0
— adjustable for S7 basic communication, max. 30
S7 message functions
Number of login stations for message functions, max. 32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 60
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 2
Status/control
● Status/control variable Yes
● Variables Inputs, outputs, memory bits, DB, times, counters
● Number of variables, max. 30
● of which status variables, max. 30
● of which control variables, max. 14
Forcing
● Forcing Yes
● Force, variables Inputs, outputs
● Number of variables, max. 10
Diagnostic buffer
● present Yes
● Number of entries, max. 500
— can be set No
— Of which powerfail-proof 100
Configuration
Configuration software
● STEP 7 Yes; 5.4 + SP2 or higher
programming
● Command set see instruction list
● Nesting levels 8
● System functions (SFC) see instruction list
● System function blocks (SFB) see instruction list
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC Yes
— GRAPH Yes
— HiGraph® Yes
Know-how protection
● User program protection/password protection Yes
Dimensions
Width 120 mm
Height 125 mm
Depth 130 mm
Weights
Weight, approx. 1 250 g